easy 10 pts Solved

2-Way LRU Tracker

Track which of two cache ways was least recently used with a single bit — the tiny piece of state behind LRU replacement in a 2-way set-associative cache.

Verilog problems / Sequential Design

What you must build

Track which of two cache ways was least recently used with a single bit — the tiny piece of state behind LRU replacement in a 2-way set-associative cache.

Engineers use “2-Way LRU Tracker” as a building block in sequential design. Interviewers ask for the same ports and the same corner cases this judge covers. Completing it in the browser is the same skill as writing synthesizable RTL at work, minus the EDA license.

Concept: For exactly two ways, LRU tracking needs only one bit: whichever way is not just accessed becomes the LRU candidate: if(access) lru_way <= ~way;. Flipping that to lru_way <= way points the tracker at the way that was just used instead of the one that wasn't — a real cache using this bit to pick an eviction victim would then evict the entry it just touched, defeating the entire purpose of LRU.

Port contract

The judge instantiates exactly these ports. Extra ports or a different module name fail to elaborate.

NameDirWidthDescription
clkinput1Clock
rstinput1Sync active-high reset (lru_way=0)
accessinput11 when a cache access happens this cycle
wayinput1Which way (0 or 1) was accessed
lru_wayoutput1The way that should be evicted next (least recently used)

How to approach this kata

This is an introductory kata. Prefer a clear continuous assignment or a small combinational always block. Name the module top_module and keep the port list identical to the table — the hidden testbench instantiates that name.

Hidden tests instantiate top_module, drive the ports, and compare every sample against a golden model. They do not grade coding style. They do grade X/Z, off-by-one counters, and ignoring enables. Sign in only when you want the run saved on the leaderboard — the specification below is public.

Starter shape

Copy this skeleton into the editor (or press Reset starter). Fill the body; do not rename the module.

module top_module(
  input  clk,
  input  rst,
  input  access,
  input  way,
  output reg lru_way
);

  // Your code here — on access, the OTHER way becomes the LRU candidate.

endmodule

Why this shows up in interviews

2-Way LRU Tracker sits under Sequential Design (sequential, cache). Concept: For exactly two ways, LRU tracking needs only one bit: whichever way is not just accessed becomes the LRU candidate: if(access) lru_way <= ~way; . Flipping that to lru_way <= way points the tracker at the way that was just used instead of the one that wasn't — a real cache using this bit to pick an eviction victim would then evict the entry it just touched, defeating the entire purpose of LRU.

A passing solution is synthesizable intent: no delays in the DUT, no initial blocks inside top_module, and no reference to testbench tasks. Use blocking assignments only in combinational always blocks; use non-blocking for registers clocked by clk.

Related problems

  • D Flip-Flop with Asynchronous Reset — Standard D flip-flop with an active-low asynchronous reset. Reset clears q immediately, without waiting for a clock edge.
  • 4-Bit Shift Register (SIPO) — Serial-in, parallel-out shift register. Each clock, shift left and load sin into the LSB. Sync active-high reset clears q.
  • JK Flip-Flop — The flip-flop with no forbidden state: j=k=1 toggles instead of racing. Classic building block for counters.
  • 4-Bit Up/Down Counter — A synchronous counter that increments or decrements each clock edge depending on a direction input, with a synchronous reset.

FAQ

What does this problem require?

What does the 2-Way LRU Tracker problem ask for? Track which of two cache ways was least recently used with a single bit — the tiny piece of state behind LRU replacement in a 2-way set-associative cache. Implement it as Verilog module top_module with the listed ports.

Combinational or sequential?

Is 2-Way LRU Tracker combinational or sequential? Tags: sequential, cache. Follow the clock/reset ports if they appear in the table; if there is no clock, use continuous assignment or combinational always @(*).

How does the auto-grader work?

How is 2-Way LRU Tracker graded? A hidden SystemVerilog/Verilog testbench in the EcrioniX judge simulates your module in the browser. You pass when every directed vector matches, including the waveform contract shown on this page.

Write a module named top_module matching the ports below exactly.
Expected waveform
Your solution
Judge output
// Output appears after you run tests.