Voltage Margin Monitor

Combinational Design · combinational, monitor, power

Flag a fault when the supply voltage strays outside its safe band in either direction — over-voltage or under-voltage, either one is a problem.

Write a synthesizable Verilog module named top_module matching the ports below exactly.
📐 Circuit Schematic Diagram
vsense[7:0]over_voltageunder_voltagefaultVOLTAGE MARGIN MONITDIGITAL HARDWARE BLOCK
⚡ Timing & Synthesizability Constraints

Timing Contract: Strict synchronous timing aligned to posedge clk or zero-delay combinational propagation.

RTL Constraints: Synthesizable Verilog-2001. No # delays in synthesizable RTL.

Concept: The two individual threshold checks are independent conditions, and a fault should fire if either one is true: fault = over_voltage || under_voltage. Using && instead of || silently changes the meaning to "both over AND under voltage at the same time" — a condition that's logically impossible for a single sensed value, so the fault output would never assert at all, no matter how far out of range the voltage strays.
NameDirWidthDescription
vsenseinput8Sensed voltage (arbitrary units)
over_voltageoutput11 if vsense > 200
under_voltageoutput11 if vsense < 50
faultoutput11 if either over or under voltage
Expected Waveform (Golden Timing Contract)
Verilog-2001 / SV Saved
Font: |
// Click Run Tests (or press Ctrl+Enter) to compile your RTL and simulate against hidden testbenches.
Simulation Timing Diagram (VCD Waveform)
100%
No simulation waveform yet. Run tests to simulate and generate VCD traces.
No compilation run yet. Syntax warnings and elaboration messages will appear here.
No simulation output yet. Raw stdout from vvp will appear here.

RTL Problems / Level 7 · Combinational Design

What You Will Learn

By solving Voltage Margin Monitor, you will acquire core industry skills:

  • Synthesizable hardware modeling in standard Verilog-2001 / SystemVerilog.
  • Correct handling of interface port contracts, edge-triggered clocks, and active-low/high resets.
  • Simulation waveform interpretation and debugging using timing diagrams (VCD traces).
  • Architectural avoidance of timing violations, glitching hazards, and synthesis warnings.

Problem Statement & Requirements

Flag a fault when the supply voltage strays outside its safe band in either direction — over-voltage or under-voltage, either one is a problem.

Hardware design teams at leading semiconductor firms evaluate these exact port contracts, race-condition assertions, and corner cases during technical design reviews and ASIC engineer interviews.

Concept: The two individual threshold checks are independent conditions, and a fault should fire if either one is true: fault = over_voltage || under_voltage. Using && instead of || silently changes the meaning to "both over AND under voltage at the same time" — a condition that's logically impossible for a single sensed value, so the fault output would never assert at all, no matter how far out of range the voltage strays.

Port List & Interface Timing

The hidden testbench instantiates top_module. Module port names and bit-widths must match the interface contract exactly:

NameDirWidthDescription
vsenseinput8Sensed voltage (arbitrary units)
over_voltageoutput11 if vsense > 200
under_voltageoutput11 if vsense < 50
faultoutput11 if either over or under voltage

Timing Constraints & Synthesizable RTL Rules

⚡ Synthesizable Implementation Guidelines

Timing Contract: Strict synchronous timing aligned to posedge clk or zero-delay combinational propagation.

Synthesis Constraints: Synthesizable Verilog-2001. No # delays in synthesizable RTL.

Starter RTL Code

module top_module(
  input  [7:0] vsense,
  output over_voltage,
  output under_voltage,
  output fault
);

  // Your code here — over_voltage=(vsense>200); under_voltage=(vsense<50); fault = over_voltage || under_voltage.

endmodule

Related RTL Problems in Level 7

  • Async-Assert / Sync-Deassert Reset — Assert reset the instant it goes active, but only release it once it has been clean for 2 clock edges — the standard reset architecture for any real design.
  • 3-Flop CDC Synchronizer — A deeper 3-stage synchronizer for signals that need extra MTBF margin beyond the standard 2-flop chain.
  • Synchronized Rising-Edge Detector — Safely synchronize an asynchronous level signal, then produce a clean single-cycle pulse the moment it rises in the local clock domain.

Frequently Asked Questions

What does Voltage Margin Monitor require?

Flag a fault when the supply voltage strays outside its safe band in either direction — over-voltage or under-voltage, either one is a problem. Implement it as Verilog module top_module matching the listed ports.

Is this design combinational or sequential?

Tags: combinational, monitor, power. If a clock signal is present in the port table, implement it as sequential logic; otherwise, use continuous assignments or combinational blocks.

How is my solution graded?

A hidden SystemVerilog testbench simulates your module in the cloud judge. You pass when all directed corner cases match the golden model and the VCD timing waveform matches the contract.

How does this challenge help with semiconductor interviews?

Technical interviewers at NVIDIA, Qualcomm, Apple, and Intel routinely ask candidates to code, debug, and explain the timing waveforms of Voltage Margin Monitor to assess real-world synthesizability and race-condition awareness.